Salta al contenuto principale

Il nostro sito web è attualmente in fase di traduzione e, di conseguenza, alcune pagine potrebbero temporaneamente apparire in inglese. Apprezziamo la vostra comprensione mentre lavoriamo per offrire un'esperienza multilingue. Grazie per la vostra pazienza!

Image
hero-gentle-lung

Gentle Lung®

Image
Gentle Lung logo

Gentle Lung® Package for Lung Protection

Patients under mechanical ventilation may suffer from ventilator-induced lung injury (VILI). This may be caused by inappropriate tidal volume (ARDSnet), inappropriate driving pressure (Amato, et al. NEJM 2015), and inappropriate PEEP (Briel M, et al. JAMA. 2010). Lung protective ventilation is a well established practice not only in ARDS patients but also in postoperative patients (Kacmarek Anesthesiology 2018).
NKV-550 ventilator offers Gentle LungTM package, which consists of four convenient tools for clinicians to practice lung protective ventilation:

Image
NKV-550 thumbnail image
Image
NKV-550 logo image


The NKV-550 Series Ventilator System is a comprehensive neonatal through adult mechanical ventilator. Relying on clinically proven modalities and features, the NKV-550 provides the clinician a highly customizable platform to help improve the outcome of the patients they care for while reducing hospital costs.

Features of App

Recruitability Assessment App: Determine Whether Your Patient Will Benefit From Lung Recruitment 

Image
Technolog Gentle Lung image 01

This app provides a guided tool for clinicians to quickly assess whether or not a particular patient will benefit from lung recruitment. The tool is easy to use. At the end of the procedure, the ventilator will display recruitable lung volume and gain in compliance.

 

 

Recruitment Maneuver App: Offers You a Tool to Conveniently Recruit Lungs

Image
Technolog Gentle Lung image 02

This app provides a guided tool for clinicians to recruit the patient’s lungs. By setting a few parameters in this app, clinicians can allow the ventilator to execute the recruitment maneuver during which the ventilator will ventilate the patient while increasing the PEEP step-by-step, eventually elevating the airway pressure to such a level that the collapsed lungs are recruited (i.e., re-opened). At the end of the procedure, the ventilator can resume normal ventilation or transition to PEEP titration, depending on the clinician’s choice.

PEEP Titration App: Titrate PEEP for Your PEEP

Image
Technolog Gentle Lung image 03

This app allows clinicians to perform a decremental PEEP titration maneuver to help identify the lowest PEEP that provides the highest lung compliance. At the end of the procedure, clinicians can either resume normal ventilation or select Recruitment Maneuver.

 

 

Transpulmonary Pressure App: Measure Driving Pressure of Your Patient

Image
Technolog Gentle Lung image 04

This app allows clinicians to conveniently monitor the transpulmonary pressure (P-tp) of the ventilated patient. In addition to real time P-tp waveform, the app measures peak value, mean value, plateau value and end expiratory value of transpulmonary pressure. The app also measures the driving pressure which is the inflation pressure of transpulmonary pressure. Talmor et al have found that adjusting PEEP setting to achieve an end expiratory transpulmonary pressure of 0 to 10 cm H2O significantly improved oxygenation and respiratory compliance in patients with ARDS (Talmor NEJM 2008). Amato, et al. has found that among all variables, driving pressure is the variable that is most strongly associated with patient survival in ARDS patients (Amato, et al. NEJM 2015).