Skip to main content
Image
Product Accessory CO2 hero image
Unique sensor for mainstream CO₂ sensor

CO2 sensors

Image
cap-ONE logo
TG-900 series

Monitor Your Patient with Reliable cap-ONE Mainstream CO2  Sensor

cap-ONE is Nihon Kohden's unique mainstream CO2 sensor for both intubated and non-intubated patients for safer respiratory management. The ultra compact and light weight sensor and unique adapter provide accurate measurements and reduce the burden on the patients.    
We have two measuring methods: the Quantitative method and the Semi-quantitative method.

Image
Image cap-one 01

Advantages and disadvantages of conventional mainstream and sidestream sensors vs the cap-ONE mainstream CO2 sensor

Image
asset cap-one 01

Mainstream CO2 sensor kit

TG-980P series

Image
asset cap-one 02

Mainstream CO2 sensor kit

TG-920P series

Mainstream CO2 sensor kit TG-980P series

Image
main cap-one 01
  • Quantitative method
  • Sensor itself weighs only 4 g
  • Accurate for both intubated and non-intubated patients
  • CO2 measurement during upper endoscopy is possible with cap-ONE Biteblock
  • Reliable even in a humid environment
  • Can be used on neonates

With a ventilator and a nebulizer

Because the mist generated in the breathing circuit by a nebulizer creates a very harsh environment for a CO2 sensor which uses infrared light, it was considered impossible to monitor CO2 by a capnometer when a nebulizer is used with a ventilator. However, we have overcome these issues and developed a TG-980P CO2 sensor that enables stable measurement over a long period of time, even when using a nebulizer.

Image
Image cap-one 02

Capnogram obtained by TG-980P, our CO2 sensor while using nebulizer

The upper waveforms are the CO2 partial pressure in exhaled air, and the lower waveform shows the signal light and reference light detected by our CO2 sensor, TG-980P. The exhaled CO2 partial pressure is calculated from the signal and reference light outputs.   
When the nebulizer is turned on, the waveforms of both the signal and reference light outputs are blurred due to the mist of the nebulizer. However, with TG-980P which is using Quantitative method, the CO2 measurement is not affected since both are equally affected so an accurate partial pressure of CO2 can be determined.

For intubated patients -Airway adapters

Image
Image cap-one 03

For non-intubated patients –cap-ONE mask and Nasal/Oral adapters

Using TG-980P CO2 sensor together with cap-ONE mask, the sensor can accurately catch oral and nasal exhaled CO2 and reliably detect respiratory variation. In addition, cap-ONE mask is easily used for pediatric patients who are receiving supplemental oxygen. With the unique design, the sensor catches the exhaled gas from the nose and mouth without interference of oxygen supply.

Image
Image cap-one 04

Efficient oxygen supply while measuring ETCO2

NPPV mask

cap-ONE and NPPV mask optimizes the ability to monitor and detect changes in the patient’s condition, improving patient care and outcomes.

Image
Image cap-one 05
  • Continuous CO2 monitoring during NPPV therapy is available
  • Designed to fit any facial shape with minimal patient discomfort and skin damage
  • Adjustable forehead cushion support arm

Increase Patient Comfort

Image
Image cap-one 08

Formfitting NPPV mask       
The Nihon Kohden NPPV mask is designed to fit any facial shape with minimal patient discomfort and skin damage.

 

Image
Image cap-one 09

Continuous CO2 monitoring during NPPV therapy      
The combination of cap-ONE, Nihon Kohden's new class of ultra-compact CO2 sensor, and unique NPPV mask optimizes the ability to monitor and detect changes in the patient's condition, improving patient care and outcomes. This is particularly useful for measuring CO2 during NPPV therapy.

 

Lineup

Image
thumb cap-one 02

Nasal/Oral adapter

Image
thumb cap-one 03

cap-ONE biteblock

  • For early detection of respiratory depression
  • Stable oxygen supply
  • Continuous monitoring of ETCO2 after endoscopy       
     

Mainstream CO2 sensor kit TG-920P series

Image
asset cap-one 02
  • Semi-quantitative method
  • No warm-up time and no calibration are required
  • Washable
  • For both intubated and non-intubated patient

For intubated patients –Airway adapters

Image
Image cap-one 06

For non-intubated patients –Nasal adapters

Image
Image cap-one 07
  • Unique design catches both nasal/oral expiration
  • Dead space volume is 1.2 ml

Go to Product Lineup page

.custom_background_column2 { display: flex; flex-wrap: wrap; } .button_tech3 { margin-top: 20px; } .custom_button_tech3 { display: flex; align-items: center; justify-content: center; width: 320px; height: 60px; font-size: 16px; border-radius: 10px; border: 1px solid #326bc9; background-color: #326bc9; text-decoration: none; margin: auto; } .custom_button_tech3:hover { background-color: #7F9CCB; border: 1px solid #7F9CCB; color: #7F9CCB; } @media screen and (max-width :768px) { .custom_button_tech3 { width: 100%; } }

Video

Material Downloads